14.Custom Killing Premises and Rural Slaughter Houses
- Scope
- 14.1Outcome
- 14.2General Principles
- 14.3Custom Killing Premises
- 14.4Rural Slaughter Houses
14.Custom Killing Premises and Rural Slaughter Houses
Scope
This section applies to the following categories of premises:
14.1Outcome
Custom Killing Premises and Rural Slaughter Houses shall be designed, constructed and located to ensure the hygienic holding, slaughter and dressing of animals and the hygienic processing, packing, storing and transporting of food and inedible materials derived from the premises.
14.2General Principles
14.3.1Stockyards
14.3.2Restraining and stunning
Restraining and stunning equipment should be designed and constructed to ensure compliance with the Animal Welfare Advisory Committee (AWAC) Code of Recommendations and Minimum Standards for the Welfare of Animals at the Time of Slaughter at Licensed and Approved Premises.
14.3.3Slaughter and dressing
Slaughter and dressing facilities shall be suitable for the intended operations of the premises and shall ensure compliance with the operational requirements of slaughter and dressing procedures.
Refer also to the applicable parts of Meat Industry Hygiene Council, Industry Standard 5: Slaughter and Dressing; and Venison Industry Standards Council, Industry Agreed Standard 5: Slaughter and Dressing.
14.3.4Ventilation
Ventilation systems shall be effective in the removal of excess heat and vapour and shall minimise the entry of contaminating odours, dust, ash, vapour and smoke.
14.3.5Lighting
Sufficient lighting shall be provided to enable accuracy of operations and hygienic processing. Artificial lights shall be either shatter-proof or enclosed in shatter-proof enclosures to prevent contamination in the event of breakage.
14.3.6Potable water
A supply of potable water, with appropriate facilities for its storage, distribution and temperature control, shall be provided in sufficient volume and pressure for the hygienic operation of the premises. Refer also to Manual 3.
14.3.7Hot water
Hot water shall be provided at a minimum temperature of 82 0C at the point of use when utilised for the sterilisation of product processing equipment, floors, walls, gut buggies, etc., that are subject to contamination.
14.3.8Drainage and sewerage system
There shall be a drainage and sewerage system that effectively removes solid and liquid waste and which does not jeopardise the hygienic processing of products.
14.3.9Equipment
14.3.10Suspension and transfer of carcasses
Unprotected carcasses, sides and quarters shall be suspended and transferred by a means that will avoid contact with walls, floors, ceilings, stands or other structures, fittings and equipment.
14.3.11Refrigeration
Adequate refrigeration facilities shall be provided for holding carcasses, sides and quarters, if deemed necessary for the approved process. Refrigerated facilities shall incorporate suitable temperature monitoring devices.
14.3.12Amenities
Amenities shall be located so as not to jeopardise the hygienic slaughter and dressing of animals and the processing, packing, storage and transport of food. Amenities shall be designed, constructed and maintained so as to:
The relevant provisions of all appropriate parts in IS 2 are applicable, with theexception of the requirements for ante- and post-mortem inspection.
New Zealand Food Safety Authority
68-86 Jervois Quay
PO Box 2835
Wellington
NEW ZEALAND
Phone: +64 4 894 2500
Fax: +64 4 894 2501
Contact
NZFSA about this page